The recent rapid adoption of electric vehicles (EVs) is creating new load characteristics in the distribution system, and in particular, the widespread use of single-phase charging methods is exacerbating phase load imbalances, leading to voltage unbalance issues. Such voltage imbalances can undermine the stability of the distribution system and may cause side effects such as reduced power quality and shortened equipment lifespan. This study proposes a smart distribution panel system that can detect voltage imbalance issues caused by uneven electric vehicle charging loads in real time and actively compensate for them. The proposed system aims to contribute to the stability and power quality improvement of the distribution network by integrating a load balancing algorithm with inter-phase voltage monitoring functionality.
The thermal management issue in OLED (organic light emitting diode) devices has a significant impact on the efficiency, reliability, and life time of the device. In particular, in OLED systems with multipolar or double cathode electrodes, it is important to accurately interpret the effect of heat generated by current flow between electrodes on the emitting layer. In this study, the governing equation was established based on the heat conduction equation to mathematically model and analyze this heat distribution, and the heat distribution analysis was performed using the COMSOL program. It was confirmed that the temperature generated in the OLED with the double cathode structure reached a maximum of 343.157 K centered on the emitting layer. The heat distribution generated in the proposed OLED structure with the double cathode electrodes was confirmed to be highly distributed in the center toward the double cathode electrodes, which is believed to be because the arrangement of the double cathode electrodes improves the symmetrical distribution of temperature while reducing power consumption.
The printed and bifacial organic photovoltaics (OPVs) using a semi-transparent electrode structure to enhance light management were investigated. To optimize energy-band alignment for bifacial device structure, a cathode interlayer of ZnO nanoparticles with a low work function of 3.9 eV combined with a polyethyleneimine (PEI) layer was employed. Photon distribution simulations revealed the influence of structural parameters on device conductivity, light absorption, and surface morphology. The dispensing strength, adjusted via applied voltage during printing, significantly impacted device performance. At 13 V and 17 V, J-V characteristics were consistent; however, at 20 V, line width increased by approximately 100%, resulting in a 50% reduction in PCE. These findings highlight the critical relationship between spraying strength, line width, and efficiency, offering valuable insights for advancing printed OPV technologies.
Mn-doped Pb(In1/2Nb1/2)O3-Pb(Mg2/3Nb1/3)O3-PbTiO3 (Mn:PIN-PMN-PT) single crystals, which exhibit improved phase transition temperatures and coercive field properties compared to Pb(In1/2 Nb1/2)O3-Pb(Mg2/3Nb1/3)O3-PbTiO3 (PIN-PMNPT) single crystals, are expected to be utilized in high-power acoustic transducers. Bridgeman method, growing single crystals along the axial direction from melt, is most widely used method for single crystal growth with large size and high quality. However, single crystal boules grown by the Bridgeman method demonstrate a PT compositional variation, giving rise a distribution of crystal structure and material properties along the growing axis. To employ piezoelectric single crystals grown by the Bridgeman method for acoustic transducers, it is essential to investigate their overall property distribution. In this study, the compositional distribution and property variation of Mn:PIN-PMN-PT single crystals grown by the Bridgeman method was investigated. Measured compositional distribution of PT was from 29% to 32.5% in the Rhombohedral crystal region of the boule. Two types of specimen, [011]-poled Mn:PIN-PMN-29PT and Mn:PIN-PMN-32PT single crystals, were fabricated and tested to obtain full property variation at both ends of the Rhombohedral crystal region. The properties related to the 32 directional vibration mode and the properties related to high-power driving were measured to confirm the overall distribution of properties by composition.
The key to determining the lifetime of OLED device is how much brightness can be maintained. It can be said that there are internal and external causes for the degradation of OLED devices. The most important cause of internal degradation is bonding and degradation in the excited state due to the electrochemical instability of organic materials. The structure of OLED modeled in this paper consists of a cathode layer, electron injection layer (EIL), electron transport layer (ETL), light emission layer, hole transport layer (HTL), hole injection layer (HIL), and anode layer on a glass substrate from top to bottom. It was confirmed that the temperature generated in OLED was distributed around the maximum of 343.15 K centered on the emission layer. It can be seen that the heat distribution generated in the presented OLED structure has an asymmetrically high temperature distribution toward the cathode, which is believed to be because the sizes of the cathode and positive electrode are asymmetric. Therefore, when designing OLED, it is believed that designing the structures of the cathode and anode electrodes as symmetrically as possible can ensure uniform heat distribution, maintain uniform luminance of OLED, and extend the lifetime. The thermal distribution of OLED was analyzed using the finite element method according to Comsol 5.2.
The insulator used for the transmission line is a device that is bonded with a cap, pin, ceramic, and cement to withstand insulation capacity and mechanical load. The insulator design can help to reduce the dispersion of the electric field; thus, the optimization of today’s design, especially as demanded power grows, is critical. The designs of four manufacturers were used to perform a comparative analysis. Under dry circumstances of the new product, an electric field distribution study was done with no pollutants attached. Manufacturer D’s design has the best voltage uniformity of 24.33% and the arc length of 500 mm or more. Manufacturer C’s design has an equalizing voltage of more than 2% higher than that of other manufacturers. The importance of the design of the insulator and the number of connections according to the installation conditions is very efficient for transmission lines that will increase in the future.
In this study, the objective is to improve the criteria used for statistical comparison of the VLF tanδ (TD) database and failure rate according to water-tree degradation in underground distribution power cables. The aging condition of the KEPCO criteria is divided into 6 levels using the Weibull distribution, and the “failure imminent” condition is quantified by using the statistical end-point of the lifetime parameter of the VLF big-data group obtained from KEPCO. Moreover, new criteria with a 2-dimensional combination of TD, DTD, and a statistical normalized factor are suggested. These criteria exhibit high reproducibility for the detection of cables in an imminent failure state. Consequently, it is expected that the adoption of the extended VLF-2019 criteria will reduce the asset management cost of cable replacement compared to the VLF-2012 criteria of KEPCO.
The aim of this investigation is to detect specific waveforms in a distribution line prior to the occurrence of a fault. Conditions were introduced such that a feeder remote terminal unit (FRTU) of the distribution automation system selects and stores fault waveforms from the different waveforms detected in the distribution line. In addition, an algorithm was developed to detect specific waveforms from the fault waveforms stored using the FRTU. This algorithm exploits the duration and periodicity of harmonic changes in voltage and current. The efficacy of the algorithm was confirmed based on the measurements of fault waveforms in an actual distribution line. The results indicated that faults in a distribution line can be predicted via experimental measurements.
Most series arcs lead to electrical fires that cannot be interrupted by circuit breakers, because the arc’s current is outside the breaker’s operating range. In this paper, experiments were conducted on the detection and identification of series arcs to prevent electrical fires. Plugs and outlets specified in KS C 8305 were deteriorated to replicate arc faults commonly found in fields. The characteristics of series arcs resulting from various types of loose connections were determined by analyzing the frequency spectra and phase distributions of detected arc pulses. The results showed that the simulated arc defects used in this study were more similar to actual arc phenomena than the existing arc generator specified in UL 1699. In addition, loose connections, such as wire-wire, terminal-wire, and outlet-plug, can be identified by phases of 0°, 180° and 360°, respectively. These phases can be detected by a band pass filter with a frequency range of 5~10 MHz, which can be used as the trip signal for circuit breakers.
Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure.In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.
It is extremely important to improve methodologies for the lifetime assessment of porcelain insulators. While there has been a considerable amount of work regarding the phenomena of lifetime distributions, most of the studies assume that aging distributions follow the Weibull distribution. However, the true underlying distribution is unknown, giving rise to unrealistic inferences, such as parameter estimations. In this article, we review several distributions that are commonly used in reliability and survival analysis, such as the exponential, Weibull, log-normal, and gamma distributions. Some properties, including the characteristics of failure rates of these distributions, are presented. We use a Bayesian approach for model selection and parameter estimation procedures. A well-known measure, called the Bayes factor, is used to find the most plausible model among several contending models. The posterior mean can be used as a parameter estimate for unknown parameters, once a model with the highest posterior probability is selected. Extensive simulation studies are performed to demonstrate our methodologies.
Degradation in power cables used in distribution lines to the material of the wire, manufacturing method, but also the line of the environment, generates a variety of degradation depending upon the type of load. The local wire deterioration weighted wire breakage accident can occur frequently, causing significant proprietary damage can lead to accidents and precious. In this study, the signal detected by the eddy current aim to develop algorithms capable of determining the signals for the top part and at least part of the signal by using a signal processing technique called K-means algorithm.
Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of 16×40×30 [mm] was used as negative electrode. In order to investigate the PD with φ-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.
This paper presents a ZigBee wireless communication system for remote diagnosis in overhead distribution power lines. The system is divided in three parts in the functional aspect - a host computer module, a remote controller module and a diagnostic system module. The host computer module designed as USB interface transmits control signals and receive data measured by sensor. The remote controller module operates the diagnostic system. Diagnostic system module communicates with internal main controller and host computer USB. Multiple communication channel is adopted for simultaneous operations of several diagnostic system. Dedicated protocol for each module is developed. The system is designed with a focus on low cost and small size suitable for lightweight and small diagnostic system.
At present, the development of a detection device in order to prevent accidents due to wire deterioration in the distribution lines is required. Distribution line is not possible to check the internal state in a normal way because it is covered with the coating. Accordingly, various eddy current techniques that is the non-destructive test (NDT) techniques have been applied to solve this problem. In this paper, we have seen examining the characteristic change of the eddy current sensor according to the simplified shape of the sensor in order to solve the problems for the simplified shape that is generated when the simulation for the shape of the eddy current sensor.
Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles (60°, 120°). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.
In this paper, plant crops used in the region to grow crops for the LED lighting area of a rectangle to fit the light distribution to maximize the efficiency of a rectangular distribution was made of LED lights. After the fabrication of LED lamps, light distribution, and in the area of 1.2 m × 3 m was the analysis of Illuminance chart. As a result of examining the performance light distribution for total Emin/Eav is 56%, and the target area of the light distribution compared to normal lamps Emin/Eav is improved by about 17%. In addition, plants grown in the area to minimize the outgoing light distribution can be focused on the cultivation area, according to the distance of the plants and be able to have the best luminous efficacy is judged.
A functionally graded material (FGM) spacer, which the distribution of dielectric permittivity inside an insulator changes spatially, can considerably reduce the electric field concentration around a high-voltage electrode and along the gas-insulator interface when compared to a conventional spacer with a uniform permittivity distribution, In this research, we propose the FGM spacer with an elliptical permittivity distribution instead of that with a distribution of dielectric permittivity varying along a radial direction only in order to improve efficiently the insulation capability. The optimal design of the elliptical FGM spacer configuration is performed by using the response surface methodology (RSM) combined with the steepest descent method (SDM).
A linear spring model, where the interactions among atoms are assumed to be isotropic and elastic, is employed for the study of non-polar optical phonon scattering in the valence band of alloy semiconductors. The force equations of n atoms are used in the spring model for the consideration of the random distribution of constituent atoms in an alloy semiconductor. When the number of atoms in a unit cell is assumed to be two based on the experimental result, the optical deformation potent is valid for compound semiconductors as well as alloy semiconductors.
The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV∼6 kV to measure the conduction current for the analysis of ion current.