In this study, using the silicone rubber sample of 4 cm × 4 cm × 0.1 cm for low voltage cable,the electrostatic electrification properties of three samples that the conductive Al of 0%, 25%, and 50% isattached to the surface of sample was measured. The following conclusion was obtained through thisexperiment. 1) In case of the sample which has the Al area of 50%, the higher the humidity to 90% in thetemperature of 10℃, the electrostatic electrification voltage was reduced about 0.25 kV to 0.02 kV, and itconfirmed that the electrostatic electrification voltage was in constant about 0.02 kV in the temperature over20℃. 2) Increasing the Al area of samples of 0%, 25%, and 50% in temperature of 10℃, it confirmed thatthe electrostatic electrification voltage was reduced by about 2.67 kV, 2.02 k, 0.21 kV. 3) This study showsthat the conductor, followed by temperature and humidity affects the electrostatic electrification voltage.