The mounting demand for sustainable, self-powered biomedical devices, particularly those engineered for extreme environments, has established triboelectric nanogenerators (TENGs) as a prominent technology in energy harvesting research. This review examines state-of-the-art biomaterial synthesis strategies essential for developing high-performance bioelectronic TENGs that can operate reliably under harsh conditions, including elevated temperatures, extreme humidity, and mechanical strain. It begins with a comprehensive overview of the fundamental principles of triboelectricity and subsequently addresses the pivotal challenges associated with efficient charge generation and retention in such challenging settings. The content places particular emphasis on recent advancements in composite material engineering and structure design for high-efficiency mechanisms, with a particular focus on biocompatible and environmentally resilient materials. The integration of TENGs into wearable sensors, implantable devices, and self-powered monitoring systems is also investigated, demonstrating their transformative potential for bioelectronic applications. Our goal subsequently underscores persistent limitations to overcome, including those pertaining to fabrication scalability and long-term operational stability, while concurrently proposing prospective research directions. Consequently, this work underscores how innovative biomaterial synthesis and bioelectronic devices can enable the development of next-generation, high-performance, self-powered devices suited for extreme biomedical environments.
For the purpose of treating health checkups and recovery of patients in a super-aged society, hospitals use devices designed with a reduction circuit of electromagnetic waves associated with the specific absorption rate of electromagnetic waves absorbed by the human body. In this paper, we proposed a filter improvement design method capable of reducing electromagnetic waves. As a result of confirming the validity of the proposed technique through simulation and experimental results, the following result values were obtained. Applying the common-mode (CM) inductor 4 mH to a calibration circuit, noise decreased in a multiband spectrum. Using the differential mode(DM) inductor 40 μH element in the primary calibration circuit, the noise decreased by 15 dB or more in the 3 MHz band spectrum. Also, applying the Admittance Capacitance (Y-Cap) 10 nF element in the secondary calibration circuit resulted in the decrease by more than 30 dB in the band spectrum before 2 MHz. After using a common-mode inductor 4 mH element in the tertiary calibration circuit, it decreased by more than 15 dB in the band spectrum after 2 MHz.
Piezoelectric generators use direct piezoelectric effects that convert mechanical energy into electrical energy. Many studies were attempted to fabricate piezoelectric generators using piezoelectrics such as ZnO, PZT, PVDF. However, these various inorganic/organic piezoelectric materials are not suitable for bio-implantable devices due to problems such as brittleness, toxicity, bio-incompatibility, bio-degradation. Thus, in this paper, piezoelectric generators were prepared using a silk fibroin film which is bio-compatible by dip-coating method. The silk fibroin films are a mixed state of silk I and silk II having stable β- sheet type structures and shows the d33 value of 8~10 pC/N. There was a difference in output voltages according to the thickness. The silk fibroin generators, coated 10 times and 20 times, revealed the power density of 16.07 μW/㎠ and 35.31 μW/㎠ using pushing tester, respectively. The silk fibroin generators are sensitive to various pressure levels, which may arise from body motions such as finger tapping, foot pressing, wrist shaking, etc. The silk fibroin piezoelectric generators with bio-compatibility shows the applicability as a low-power implantable piezoelectric generator, healthcare monitoring service, and biotherapy devices.
In this paper, the effect of hot carrier injection on an n-bulk fin field-effect transistor (FinFET) is analyzed. The hot carrier injection method is applied to determine the performance change after injection in two ways, channel hot electron (CHE) and drain avalanche hot carrier (DAHC), which have the greatest effect at room temperature. The optimum condition for CHE injection is VG=VD, and the optimal condition for DAHC injection can be indirectly confirmed by measuring the peak value of the substrate current. Deterioration by DAHC injection affects not only hot electrons formed by impact ionization, but also hot holes, which has a greater impact on reliability than CHE. Further, we test the amount of drain voltage that can be withstood, and extracted the lifetime of the device. Under CHE injection conditions, the drain voltage was able to maintain a lifetime of more than 10 years at a maximum of 1.25 V, while DAHC was able to achieve a lifetime exceeding 10 years at a 1.05-V drain voltage, which is 0.2 V lower than that of CHE injection conditions.
Al thin films were deposited on TiN/Si(100) via metal-organic chemical vapor deposition using N-methylpyrrolidine alane as a precursor. Characterization of the deposited films were investigated with SEM, XRD, α-step, AFM, 4-point probe. The early stage of Al thin film deposition was analyzed by in-situ surface reflectance measurement with laser and photometer apparatus. The surface reflectance were changed greatly during the initial 30∼40 seconds. There were two increases and two decreases in the surface reflectance, thus the sequence of Al films were deposited at 8 significant points of the surface reflectance change. Surface topograph and cross-sectional view of each film were analyzed with SEM. Al films were grown in the complex mechanism of Volmer-Weber and Stranski-Krastanov process.
In order to develop a LED luminaire for naval-submarines which can replace a conventional one with two-compact fluorescent lamp (CFL) of 18 W, we analyzed the electrical and optical performance of the conventional luminaire. A LED luminaire was fabricated as compact as possible based on the analyzed data. The weight of the prototype LED luminaire is 1.8 kg, reducing up to 58% of the conventional one. The use of LED package for the submarine luminaire could reduce the power consumption from 38 W to 14.5 W with the same optical performance. The reason is that the optical efficacy of the LED luminaire improved by 2.47 times as 61.9 lm/W, compared to 25.1 lm/W for the conventional one.
Reported here are results of the mechanical and electrical properties of both of intact and thermally degraded epoxy-coated copper busducts that are made by fluidized bed process. To elucidate and compare the properties mentioned above, electrical breakdown by thermal and water aging, v-t characteristic, bending test, impact test and cross cut test are carried out. Although the performance of electrical and mechanical properties are gradually decreased in increasing the severe conditions such as temperature, aging time, and so forth, sample C has a better performance in both mechanical and electrical properties.
We fabricated fully depleted (FD) SOI-based 1T-DRAM cells with planar channel or recessed channel and the electrical characteristics were investigated. In particular, the dependence of memory operating mode on the channel structure of 1T-DRAM cells was evaluated. As a result, the gate induced drain leakage current (GIDL) mode showed a better memory property for planar type 1T-DRAM. On the other hand, the impact ionization (II) mode is more effective for recessed type.
Piezoelectric materials can be used to convert mechanical energy into electrical energy. In this study, we investigated the possibility of harvesting from mechanical vibration force using a high efficient piezoelectric material-polyvinylidene fluoride (PVDF). A piezoelectric energy harvesting system consists of rectifier, filter capacitor, resistance. The experiments were carried out with impacting force to PVDF film with the thickness of 1 ㎛. The output power was measured with change in the load resistance value from 100 Ω to 2.2 MΩ. The highest power was obtained under optimization by selection of suitable resistive load and capacitance. A power of 0.3082 μW/mm2 was generated at the external vibration force of 5 N (10 Hz) across a 1 MΩ optimal resistor. Also, the maximum power of 0.345 μW/mm2 was generated at 22 μF and 1 MΩ. The developed system was expected at a solution to overcome the critical problem of making up small size energy harvester.
Abstract: The continuous increase demand for electric power leads to the additional construction of transmission facilities, but it is not easy to acquire right-of-way for transmission facilities. Therefor, there is a need for compact tower that can be built on a narrow right-of-way. the compact tower with polymer insulation arm is a solution. It can be upgrading conventional 154 kV transmission line voltages to 345 kV levels. However transmission voltage is increasing, environment interference (corona noise, radio interference, etc.) will occur gradually. This environment interference is depending on the electrical clearances of tower and configuration of conductors. Therefore the analysis of the factors of environmental interference is necessary in order to upgrading transmission voltage. This paper presents the design factor of a compact tower to meet the environmental interference standard.