The quench behavior of wires for superconducting fault current limiters at DC faults was simulated, with a focus on the effect of capacitor discharge on the quench. The behavior was also expressed in mathematical forms to facilitate a better understanding of the simulation results and for rough analytical estimations of the wire length suitable for the circuit voltage and capacitance. The quench resistance development behavior for various wire lengths and circuit capacitances was simulated using the model developed in the previous work. The quench behavior was expressed in mathematical forms, reflecting the concept of heat balance. During the quench, the wire temperature increased more slowly for longer wires, but was found to increase in a similar pattern. The wire length estimated by the mathematical formula was close to the one obtained by the simulation, with an error range of a few %. The calculations will be used to estimate effectively the length of wires needed to build superconducting fault current limiters for applications in DC power systems.
The quench behavior of coated conductors (CCs) was simulated with a focus on the initial stage of quenches, and the current limiting behavior of superconducting fault current limiters (SFCLs) at DC faults was calculated. Since the fault current reaches the peak in several ms in DC lines due to capacitor discharge, it is necessary to understand the initial quench behavior well. Considered in the simulation are characteristics of CCs in the flux-flow state, current sharing, non-uniform critical current distribution in CCs, and heat transfer to surroundings. The simulation fit data well. Using the CC model developed in the simulation, the current limiting behavior of SFCLs made of CCs at DC faults was calculated. Critical current distribution and heat transfer were found to affect the current limiting behavior of SFCLs less at DC faults. The calculation will contribute to the effective design of SFCLs for applications in DC lines.
Eu3+-doped BaZrO3 (BaZrO₃:Eu³++) phosphor powders were prepared using a solid-state reaction by changing the molar concentration of Eu3+ within the range of 0.5 to 30 mol%. Irrespective of the molar concentration of Eu3+ ions, the crystal structures of all the phosphors were cubic. The excitation spectra of BaZrO₃:Eu³++ phosphors consisted of an intense broad band centered at 277 nm in the range of 230~320 nm. The emission spectra were composed of a dominant orange band at 595 nm arising from the 5D0→7F1 magnetic dipole transition of Eu3+ and two weak emission bands centered at 574 and 615 nm, respectively. As the concentration of Eu3+ increased from 0.5 to 10 mol%, the intensities of all the emission bands gradually increased, approached maxima at 10 mol% of Eu3+ ions, and then showed a decreasing tendency with further increase in the Eu3+ ions due to the concentration quenching. The critical distance between neighboring Eu3+ ions for concentration quenching was calculated to be 11.21 Å, indicating that dipole-dipole interaction was the main mechanism of concentration quenching of BaZrO₃:Eu³++ phosphors. The results suggest that the orange emission intensity can be modulated by doping the appropriate concentration of Eu3+ ions.
The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.
In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.
Durability of superconductors used to fabricate superconducting power machines is important, since the machines need to operate stably. Quench properties of GBCO (GdBa2Cu3O7) coated conductor tapes laminated with brass were measured and analyzed to investigate the durability of tapes under repeated short-circuit conditions. With short currents applied to the tapes repeatedly, the quench properties of tapes were measured, and bubbles generated during quenches were observed. The results showed that quench resistance and distribution were maintained after repeated quenches. They were maintained after repeated quenches at various applied voltages, which show durability of the tapes under repeated short-circuit conditions. The quench distribution was uniform throughout repeated quenches, which contributed to the durability of tapes.
New white-light-emitting SrSnO3:Dy3+ phosphors were prepared using different concentrations of Dy3+ ions via a solid-state reaction. The phase structure, luminescence, and morphological properties of the synthesized phosphors were investigated using X-ray diffraction analysis, fluorescence spectrophotometry, and scanning electron microscopy, respectively. All the synthesized phosphors crystallized in an orthorhombic phase with a major (020) diffraction peak, irrespective of the concentration of Dy3+ ions. The excitation spectra were composed of a broad band centered at 298 nm, ascribed to the O2--Dy3+ charge transfer band and five weak bands in the range of 350~500 nm. The emission spectra of SrSnO3:Dy3+ phosphors consisted of three bands centered at 485, 577, and 665 nm, corresponding to the 4F9/2→6H15/2, 4F9/2→6H13/2, and 4F9/2→6H11/2 transitions of Dy3+, respectively. As the Dy3+ concentration increased from 1 to 15 mol%, the intensities of all the emission bands gradually increased, reached maxima at 15 mol% of Dy3+ ions, and then decreased rapidly at 20 mol% due to concentration quenching. The critical distance between neighboring Dy3+ ions for concentration quenching was calculated to be 9.4 Å. The optimal white light emission by the SrSnO3:Dy3+ phosphors was obtained when the Dy3+ concentration was 15 mol%.
The white light of a hybrid LED is obtained by using red and green organic fluorescent layers made of polymethylmethacrylate (PMMA) films, which function as color down-conversion layers of blue light-emitting diodes. In this research, we studied the fluorescence properties of a red organic fluorophore, employing perylene bisimide derivatives applicable to hybrid LEDs. The solubility, thermal stability, and luminous efficiency are important characteristics of organic fluorophores for use in hybrid LEDs. The perylene fluorescent compounds (1A and 1B) were prepared by the reaction of 4-bromophenol and 4-iodophenol with N,N`-bis(4-bromo-2,6-diisopropylphenyl)-1, 6,7,12-tetrachloroperylene-3,4,9,10-tetracarboxyl diimide (1) in the presence of dimethyl formaldehyde (DMF) at 70℃. The synthesized derivatives were characterized by using 1H-NMR, FT-IR, UV/Vis absorption and PL spectra, and TGA analysis. Compounds 1A and 1B showed absorption and emission at 570 nm and 604 nm in the UV/Vis spectrum. We also documented favorable solubility and thermal stability characteristics of the perylene fluorophores in our work. Perylene fluorophore 1, with the 4-bromophenol substituent 1A, exhibited particularly good thermal stability and solubility in organic solvents.
In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two high-TC superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both 0° and 90° fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.
In this paper, we analyzed the power consumption and the accumulated energy in HTSC (high-TC superconducting elements) according to the resistance of HTSC element and the winding current of transformer type SFCL (superconducting fault current limiter) using double quench. For the analysis, two different inductances of the one secondary winding among two secondary windings comprising the transformer type SFCL were selected and the short-circuit tests were carried out. The consumed power and the accumulated energy in HTSC element connected into the secondary winding with larger inductance were analyzed to be larger compared to the one connected into the secondary winding with lower inductance.
In this paper, we analyzed the operational characteristics of the fault current limiting according to the amplitude of the fault current for the transformer type superconducting fault current limiter (SFCL). If the fault current happens, the superconducting element connected to the secondary coil is occurred quench and the fault current is limited. When the larger fault current occurs, the superconducting element connected to the third coil is occurred additional quench and the peak fault current is limited. We found that the fault current can be more effectively controlled through the analysis of the fault current limiting and the short-circuit tests.
The flux-lock type superconducting fault current limiter (SFCL) connects the two parallel windings in parallel with a ferromagnetic core. We suggest that the double quench flux-lock type SFCL should add a third winding. We analyzed characteristics of the fault current and the peak current using the quench of the high-Tc superconducting element. The proposed SFCL’s inductances of a primary winding and the third winding were fixed and the amplitude of inductance of the secondary winding was changed. We found that the fault current can be more effectively controlled through the analysis of the equivalent circuit and the short-circuit tests.
The second-generation HTS wire its YBCO coated conductor is widely used in the superconducting power apparatus. The YBCO coated conductor uses the normal-superconducting junction to increase the transport capacity of superconducting power apparatus when it is applied. The normal-superconducting junction can be a cause of reducing the stability of the superconducting power apparatus when a fault current is applied. Thus, in this study we have conducted the effect analysing normal-superconducting junction for the fault current using transport current and quench resistance. From the experimental results when a fault current is applied, the effect on the normal-superconducting junction is reduced the larger the amplitude of the fault current and is helpful to maintain the thermal stability of the HTS wire.