Skip to main navigation Skip to main content
  • KIEEME

J Electr Electron Mater : Journal of Electrical and Electronic Materials

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

5
results for

"Packaging"

Keywords

Publication year

Authors

"Packaging"

Study on Reliability of Vapor Cell by Laser Packaging with Au/Au-Sn Heterojunction
Jin Gu Kwon, Yong Min Jeon, Ji Young Kim, Eun Byeol Lee, Seong Eui Lee
J Electr Electron Mater 2020;33(5):367-372.   Published online September 1, 2020
DOI: https://doi.org/10.4313/JKEM.2021.33.5.6
As packaging processes for atomic gyroscope vapor cells, the glass tube tip-off process, anodic bonding, and paste sealing have been widely studied. However, there are stability issues in the alkali metal which are caused by impurity elements and leakage during high-temperature processes. In this study, we investigated the applicability of a vapor cell low-temperature packaging process by depositing Au on a Pyrex cell in addition to forming an Au-Sn thin film on a cap to cover the cell, followed by laser irradiation of the Au/Au-Sn interface. The mechanism of the thin film bonding was evaluated by XRD, while the packaging reliability of an Ne gas-filled vapor cell was characterized by variation of plasma discharge behavior with time. Furthermore, we confirmed that the Rb alkaline metal inside the vapor cell showed no color change, indicating no oxidation occurred during the process.
  • 10 View
  • 0 Download
The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor
Sun-jong Lee, Jong-chang Woo
J Electr Electron Mater 2020;33(5):350-354.   Published online September 1, 2020
DOI: https://doi.org/10.4313/JKEM.2021.33.5.3
In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.
  • 9 View
  • 0 Download
A Study on the Hermetic Method for Packaging of Implantable Medical Device
Jae-soon Park, Sung-il Kim, Eung-bo Kim, Young-hwan Kang, Sung-hwan Cho, Yeun-ho Jounga
J Electr Electron Mater 2017;30(7):407-412.   Published online July 1, 2017
This paper introduces a biocompatible packaging system for implantable medical device having a hermetic sealing, such that a perfect physical and chemical isolation between electronic medical system and human body (including tissue, body fluids, etc.) is obtained. The hermetic packaging includes an electronic MEMS pressure sensor, power charging system, and bluetooth communication system to wirelessly measure variation of capacitance. The packaging was acquired by Quartz direct bonding and CO2 laser welding, with a size of width 6 cm × length 10 cm × height 3 cm. Hermetic sealing of the packaged system was tested by changing the pressure in a hermetic chamber using a precision pressure controller, from atmospheric to 900 mmHg. We found that the packaged system retained the same count or capacitance values with sensor 1 - 25,500, sensor 2 - 26,000, and sensor 3 - 20,800, at atmospheric as well as 900 mmHg pressure for 5 hours. This result shows that the packaging method has perfect hermetic sealing in any environment of the human body pressure.
  • 9 View
  • 0 Download
A Study on Improvement of Optical Characteristics by Packaging Methods in Three Electrode-Type Reflective Display
Sang-hyun Park, Young-cho Kim
J Electr Electron Mater 2017;30(3):170-174.   Published online March 1, 2017
In 3 electrode reflective displays using a plastic substrate, unstable packaging induces particle clumping and optical degradation due to external air inflow and electronic ink evaporation. In this work, we fabricate 3 electrode electronic paper using glass wafer, ITO/plastic film, and ITO/glass/gas barrier film as an upper substrate after injecting electronic ink onto the lower substrate. Then, we studied its properties. After operating under stress conditions for 336 hours at 85℃ and 75% humidity, the reflectivity of driven e-paper panels with white color was 25.5% for the panels using glass wafer, 22.5% for plastic film including a gas barrier layer, and 16% for plastic film only. From these optical properties, we conclude that gas barrier film improves upper film isolation as a desirable packaging method.
  • 10 View
  • 0 Download
RF High Power Amplifier Module using AIN Substrate
Seung Yong Kim, Choong Mo Nam
J Electr Electron Mater 2009;22(10):826-831.   Published online October 1, 2009
  • 6 View
  • 0 Download