Skip to main navigation Skip to main content
  • KIEEME

J Electr Electron Mater : Journal of Electrical and Electronic Materials

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

3
results for

"Impedance meter"

Keywords

Publication year

Authors

"Impedance meter"

Regular Paper : Thin Films and Sensors ; Analysis of the Electrical Properties of Solar Cell According to Variation of the Frequency
Seong Geol Kim, Chang Woo Hong, Kyung Sup Lee
J Korean Inst Electr Electron Mater Eng 2012;25(5):372-376.   Published online May 1, 2012
DOI: https://doi.org/10.4313/JKEM.2012.25.5.372
This study focused on the performance characteristics of solar cell using the impedance technique. We measured an impedance according to frequency from 1 Hz until 1 MHz. It could know that the impedance was decreased according to the frequency increases in solar cell. The impedance of single crystal solar cell was 0.61 Ω at 1 Hz, and kept almost settled value to 1×10(2) Hz. However, the impedance of polycrystal solar cell was 7×10(3) Ω at 1 Hz.

Citations

Citations to this article as recorded by  
  • Electric Degradation of Failure Mode of Solar Cell by Thermal Shock Test
    Min-Soo Kang, Yu-Jae Jeon, Young-Eui Shin
    Journal of Energy Engineering.2013; 22(4): 327.     CrossRef
  • 186 View
  • 0 Download
  • 1 Crossref
Regular Paper : Thin Films and Sensors ; Analysis of Electrical Characteristics for Single Crystalline and Poly-crystalline Solar Cell
Chang Woo Hong, Yong Sung Choi, Kyung Sup Lee, Soo Young Cho
J Korean Inst Electr Electron Mater Eng 2011;24(9):744-749.   Published online September 1, 2011
DOI: https://doi.org/10.4313/JKEM.2011.24.9.744
Recently, annual usage of energy is dramatically increasing because industrialization is going faster and more electricity is needed due to various electronic devices. This study focused on the performance characteristics of solar cell using the impedance technique. The experiment measured an impedance according to frequency`s from 2 mHz until 1 MHz. It could know that the impedance was decreased according to the frequency increases in solar cell. The imaginary part was changed from capacitance component to inductance component.
  • 146 View
  • 0 Download
Design and Fabrication of a Wideband Ground Impedance Meter
Dae Won Park, Gyung Suk Kil, Ju Seop Han, Un Yong Jang, Young Jun Gil
J Korean Inst Electr Electron Mater Eng 2010;23(10):793-797.   Published online October 1, 2010
DOI: https://doi.org/10.4313/JKEM.2010.23.10.793
The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.
  • 146 View
  • 0 Download