Skip to main navigation Skip to main content
  • KIEEME

J Electr Electron Mater : Journal of Electrical and Electronic Materials

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

24
results for

"Current Limiting"

Keywords

Publication year

Authors

"Current Limiting"

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types
Shin-won Lee, Tae-hee Han, Sung-hun Lim
J Korean Inst Electr Electron Mater Eng 2023;36(6):614-619.   Published online November 1, 2023
DOI: https://doi.org/10.4313/JKEM.2023.36.6.13
The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.
  • 171 View
  • 0 Download
Analysis on Fault Current Limiting Operation of Three-Phase Transformer Type SFCL Using Double Quench
Tae-hee Han, Seok-cheol Ko, Sung-hun Lim
J Korean Inst Electr Electron Mater Eng 2022;35(2):184-189.   Published online March 1, 2022
DOI: https://doi.org/10.4313/JKEM.2022.35.2.12
In this paper, the fault current limiting operations of three-phase transformer type superconducting fault current limiter (SFCL) using double quench, which consisted of E-I iron core with three legs wound by primary and secondary windings and two superconducting modules (SCMs), were analyzed according to three-phase ground fault types. To verify the effective operation of the three-phase transformer type SFCL using double quench, the test circuit for three-phase ground faults was constructed, and the fault current tests were carried out. Through analysis on the fault current test results, the different fault current limiting characteristics of three-phase transformer type SFCL using double quench from three-phase transformer type SFCL using three SCMs were discussed.
  • 139 View
  • 0 Download
Transient Current Limiting Characteristics of Flux-Lock Type SFCL Using Double Quench
Sang-jae Choi, Sung-hun Lim
J Korean Inst Electr Electron Mater Eng 2017;30(2):96-100.   Published online February 1, 2017
DOI: https://doi.org/10.4313/JKEM.2017.30.2.96
In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two high-TC superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both 0° and 90° fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.
  • 154 View
  • 0 Download
Analysis on Current Limiting and Magnetizing Characteristics Due to Winding Locations of Superconducting Fault Current Limiter Using E-I Core
Bo-hee Kim, Sang-jae Choi, Sung-hun Lim
J Korean Inst Electr Electron Mater Eng 2017;30(2):106-110.   Published online February 1, 2017
DOI: https://doi.org/10.4313/JKEM.2017.30.2.106
This paper compared current limiting characteristics of superconducting fault current limiter (SFCL) using E-I core due to the location of windings. Since E-I core has three legs and two magnetic paths, the current limiting characteristics of SFCL were expected to be affected by the installation location of windings, either center leg or right/left leg. To analyze its characteristics, the electrical equivalent circuit of the SFCL were derived and the electromagnetic analysis for the SFCL with the designed structure were performed. From the short-circuit tests, the hysteresis curve and the voltage-current trajectory of the SFCL due to the installation location of windings were extracted and compared each other. The SFCL with windings in the center leg of E-I core was shown to be larger magnetizing inductance compared to the one with windings in the right or left leg of E-I, which was analyzed from the hysteresis curve. In addition, larger decreased fault current right after the fault occurrence in the SFCL with windings in the center leg of E-I core was confirmed than the SFCL with windings in the right or left leg of E-I.
  • 139 View
  • 0 Download
Analysis on Fault Current Limiting Characteristics of Flux-Lock Type SFCL Using Magnetic Flux Application Circuit
Ju-chan Go, Seung-taek Lim, Sung-hun Lima
J Korean Inst Electr Electron Mater Eng 2017;30(1):37-41.   Published online January 1, 2017
DOI: https://doi.org/10.4313/JKEM.2017.30.1.37
In this paper, the fault current limiting characteristics of the flux-lock type SFCL (superconducting fault current limiter) using magnetic application circuit were analyzed. The flux-lock type SFCL has the structure to install the magnetic application circuit, which can increase the resistance of HTSC (high-TC superconducting element comprising) the SFCL. To analyze the fault current limiting effect of the flux-lock type SFCL through the magnetic flux application circuit, the flux-lock type SFCL either with the magnetic flux circuit or without the magnetic flux circuit was constructed and the fault current limiting characteristics of the SFCL were compared each other through the short-circuit tests.
  • 154 View
  • 0 Download
Evaluation on the Properties of the Current Limiting Part for Fault-Current-Limiting Type HTS Cables
Tae Min Kim, Gong Hyun Hong, Byung Sung Han, Ho Ik Du
J Korean Inst Electr Electron Mater Eng 2015;28(3):191-195.   Published online March 1, 2015
DOI: https://doi.org/10.4313/JKEM.2015.28.3.191
Inside the existing superconducting cables, the superconducting wire carries a loss-free current, and the cable former (the stranded copper wire) bypasses the fault current to prevent damage and loss of the superconducting cable when the fault current is applied. The fault-current-limiting-type superconducting cable proposed in this paper usually carries a steady current; but in a fault state, the cable generates self-resistance that makes the fault current lower than a certain width. That is, the superconducting cable that transmitted only a low voltage and a large capacity power repetitively limits the fault current, as does a superconducting current limiter. To complete this structure, it is essential to investigate the mutual resistance relationship between the superconducting wires after applying a fault current. Therefore, in this paper, one kinds of superconducting wires (a wire without a stabilization layer) were connected parallel 4 tapes, respectively; and after applying a fault current, the current, voltage, resistance and thermal stability of the HTS thin-film wires were examined.
  • 142 View
  • 0 Download
Superconductor and Magnetic Materials Evaluation on the Properties of the Current Transporting Part for Fault-Current-Limiting Type HTS Cables
Tae Min Kim, Gong Hyun Hong, Byung Sung Han, Ho Ik Du
J Korean Inst Electr Electron Mater Eng 2014;27(10):657-661.   Published online October 1, 2014
DOI: https://doi.org/10.4313/JKEM.2014.27.10.657
When an abnormal condition occurs due to a fault current at a consumer location whereelectricity is supplied through high-Tc superconducting(HTS) cable, the HTS cable would be damaged ifthere is no appropriate method to protect it. The fault-current-limiting type HTS cable that is suggestedin this study has a structure of transport part and limit part. It conduct a zero impedance transportcurrent at ordinary operations and carry out a fault current limiting at extraordinary operations. To makea perfect this structure, it is essential to investigate electrical properties of transport part that comprisethe fault-current-limiting type HTS cable. In this paper, transport part that comprise HTS wire withcopper stabilization layer is examined the current transport properties and the stability evaluation.
  • 147 View
  • 0 Download
Study on Selection of HTS Wire for Fabrication of Fault Current-limiting Type HTS Cables
Soung Ouk Heo, Tae Min Kim, Byung Sung Han, Ho Ik Du
J Korean Inst Electr Electron Mater Eng 2013;26(12):904-908.   Published online December 1, 2013
DOI: https://doi.org/10.4313/JKEM.2013.26.12.904
When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through a high-capacity and high-Tc superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate measure to protect it. Therefore, appropriate measures are needed to protect HTS cables. The fault-current-limiting HTS cable that was suggested in this study performs an ideal transport current function in normal operations and plays a role in limiting a fault current in abnormal operation (i.e., when a fault current is applied). It has a structure that facilitated its self-current-limiting ability through device change and reconfiguration in the existing HTS cable without extra switching equipment. To complete this structure, it is essential to investigate about the selection of the superconducting wire. Therefore, in this paper, HTS wire using two types of different stabilization layer is compared and examined the stability and current limiting properties under the existence of a fault current.
  • 148 View
  • 0 Download
Current Limiting Characteristics of a SFCL with Two Triggered Current Limiting Levels in a Simulated Power Distribution System
Seok Cheol Ko, Tae Hee Han
J Korean Inst Electr Electron Mater Eng 2013;26(2):134-139.   Published online February 1, 2013
DOI: https://doi.org/10.4313/JKEM.2013.26.2.134
When the accident occurred in power distribution system, it needs to control efficiently the fault current according to the fault angle and location. The flux-lock type superconducting fault current limiters (SFCL) can quickly limit when the short circuit accidents occurred and be made the resistance after the fault current. The flux-lock type SFCL has a single triggering element, detects and limits the fault current at the same time regardless of the size of the fault current. However, it has a disadvantage that broken the superconductor element. If the flux-lock type SFCL has separated structure of the triggering element and the limiting element, when large fault current occurs, it can reduce the burden of power and control fault current to adjust impedance. In this paper, this system is composed by triggering element and limiting element to analyze operation of limiting current. When the fault current occurs, we analyzed the limiting and operating current characteristics of the two triggering current level, and the compensation characteristics of bus-voltage sag according to the fault angle and location.
  • 155 View
  • 0 Download
Superconductor and Magnetic Materials : Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding
Tae Hee Han, Sung Hun Lim
J Korean Inst Electr Electron Mater Eng 2011;24(2):136-140.   Published online February 1, 2011
DOI: https://doi.org/10.4313/JKEM.2011.24.2.136
The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.
  • 148 View
  • 0 Download
Regular Paper : Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function
Tae Hee Han, Sung Hun Lim
J Korean Inst Electr Electron Mater Eng 2011;24(1):47-51.   Published online January 1, 2011
DOI: https://doi.org/10.4313/JKEM.2011.24.1.47
The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

Citations

Citations to this article as recorded by  
  • Double Peak Current Limiting Properties of Series Connection-Type SFCL with Two Magnetic Paths
    Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
    Journal of the Korean Institute of Illuminating and Electrical Installation Engineers.2014; 28(7): 62.     CrossRef
  • 188 View
  • 0 Download
  • 1 Crossref
Analysis on Hysteresis Characteristics of a Transformer Type Superconducting Fault Current Limiter
Sung Hun Lim
J Korean Inst Electr Electron Mater Eng 2010;23(2):164-168.   Published online February 1, 2010
DOI: https://doi.org/10.4313/JKEM.2010.23.2.164
  • 148 View
  • 0 Download
  • 153 View
  • 0 Download
Analysis on Reduction Method of Symmetrical Fault Current in a Power System with a SFCL applied into Neutral Line
Sung Hun Lim
J Korean Inst Electr Electron Mater Eng 2010;23(2):148-152.   Published online February 1, 2010
DOI: https://doi.org/10.4313/JKEM.2010.23.2.148
  • 141 View
  • 0 Download
Hysteresis Characteristics of a SFCL using a Magnetic Coupling of Coils with an Iron Core of Two Magnetic Paths
Sung Hun Lim
J Korean Inst Electr Electron Mater Eng 2009;22(12):1073-1077.   Published online December 1, 2009
DOI: https://doi.org/10.4313/JKEM.2009.22.12.1073
  • 140 View
  • 0 Download
Current Limiting Characteristics according to Applied Voltage Increase of Resistive-type SFCL using YBCO Coated Conductor
Ho Ik Du, Min Ju Kim, Seung Gyu Doo, Yong Jin Kim, Dong Hyeok Lee, Byoung Sung Han
J Korean Inst Electr Electron Mater Eng 2009;22(10):854-859.   Published online October 1, 2009
DOI: https://doi.org/10.4313/JKEM.2009.22.10.854
  • 129 View
  • 0 Download
Operating Characteristics of Transformer Type SFCL with Resistor in Tertiary Winding
Byoung Hwan Choi, Byoung Sung Han
J Korean Inst Electr Electron Mater Eng 2008;21(12):1111-1117.   Published online December 1, 2008
DOI: https://doi.org/10.4313/JKEM.2008.21.12.1111
  • 116 View
  • 0 Download
Analysis on Quench Velocity of SFCL dependent on Source Voltage
J Korean Inst Electr Electron Mater Eng 2007;20(10):889-894.   Published online October 1, 2007
DOI: https://doi.org/10.4313/JKEM.2007.20.10.889
  • 123 View
  • 0 Download
Recovery Characteristics of a Flux-Lock Type HTSC Fault Current Limiter after Fault Removal
J Korean Inst Electr Electron Mater Eng 2007;20(9):812-815.   Published online September 1, 2007
DOI: https://doi.org/10.4313/JKEM.2007.20.9.812
  • 152 View
  • 0 Download
Analysis on Operational Current and Current Distribution between Two Coils of Flux-Lock Type SFCL
J Korean Inst Electr Electron Mater Eng 2005;18(8):753-758.   Published online August 1, 2005
DOI: https://doi.org/10.4313/JKEM.2005.18.8.753
  • 129 View
  • 0 Download
  • 137 View
  • 0 Download
AC Loss Characteristic in the Fault Current Limiting Elements of a Coil Type
J Korean Inst Electr Electron Mater Eng 2005;18(4):370-374.   Published online April 1, 2005
DOI: https://doi.org/10.4313/JKEM.2005.18.4.370

Citations

Citations to this article as recorded by  
  • Influence of the conductor’s arrangement and current on the AC loss characteristics of a fault current limiting coil
    Z.Y. Li, Y.H. Ma, K. Ryu, S. Choi, K.B. Park, I.S. Oh
    Physica C: Superconductivity.2008; 468(15-20): 2063.     CrossRef
  • 181 View
  • 0 Download
  • 1 Crossref
  • 126 View
  • 0 Download
Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse
Hyo Sang Choi
J Korean Inst Electr Electron Mater Eng 2004;17(6):673-677.   Published online June 1, 2004
DOI: https://doi.org/10.4313/JKEM.2004.17.6.673
  • 130 View
  • 0 Download