Skip to main navigation Skip to main content
  • KIEEME

J Electr Electron Mater : Journal of Electrical and Electronic Materials

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Page Path

2
results for

"Capacitive probe"

Keywords

Publication year

Authors

"Capacitive probe"

Regular Paper : Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers
Kwang Seok Jung, Dae Won Park, Hyeon Kyu Cha, Sang Wook Cha, Gyung Suk Kil
J Korean Inst Electr Electron Mater Eng 2011;24(4):319-324.   Published online April 1, 2011
DOI: https://doi.org/10.4313/JKEM.2011.24.4.319
This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]∼45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.

Citations

Citations to this article as recorded by  
  • Machine Learning-Based Partial Discharge Recognition in Cast-resin transformers Using Phase-Synchronized Partial Discharge Detection Technique
    Gyeong-Yeol Lee, Gyung-Suk Kil
    Journal of Electrical Engineering & Technology.2026; 21(6): 5147.     CrossRef
  • 91 View
  • 0 Download
  • 1 Crossref
A Study on PD Detection Methods for Cast-resin Dry-type Transformers
Chan Yong Park, Dae Won Park, Jae Sung Choi, Gyung Suk Kil
J Korean Inst Electr Electron Mater Eng 2009;22(9):786-791.   Published online September 1, 2009
DOI: https://doi.org/10.4313/JKEM.2009.22.9.786

Citations

Citations to this article as recorded by  
  • Nb-embedded Janus WSSe monolayer as a resistive or Schottky gas sensor upon CO, HCHO and C2H3Cl in dry transformers: a first-principles investigation
    Dan He, Guangming Li, Wen Cao, Hao Cui
    Physics Letters A.2025; 553: 130669.     CrossRef
  • DFT simulations of Al-doped MoTe 2 monolayer as an HCHO and C 2 H 3 Cl gas sensor for status evaluation of a dry-type reactor in the HVDC converter station
    Pei Guo, Chao Xiao, Meng Yao, Yao Liu, Jing Hu, Jian Hu, Tai Li
    Molecular Physics.2025;[Epub]     CrossRef
  • Fault signature gas sensing by the Ni-dispersed SnS 2 monolayer for operation status evaluation of dry-type transformer: a first-principles study
    Zhigang Chen, Chaoliang Qi, Xin Chen, YuZhe Bao, Yanan Yang, Fan Zhou
    Molecular Physics.2025;[Epub]     CrossRef
  • Single Ni Atom-Dispersed WSe2 Monolayer for Sensing Typical Fault Gases in Dry-Type Transformers: A First-Principles Study
    Yan Liu, Jianben Liu, Zhuo Wei, Tian Yuan, Hao Cui
    ACS Omega.2023; 8(49): 47067.     CrossRef
  • Implementation of Prediction Program for Deterioration Judgment on Substation Power Systems in Urban Railway
    Ho-Sung Jung, Young Park, Hyun-Il Kang
    The Transactions of The Korean Institute of Electrical Engineers.2013; 62(6): 881.     CrossRef
  • 78 View
  • 0 Download
  • 5 Crossref